Gravity: SFA40 Formaldehyde (HCHO) Sensor (0-1000ppb, ±20ppb Accuracy)

7.860,00 EGP

Category:
Description

Gravity: SFA40 HCHO Sensor is a high‑precision electrochemical module built for accurate formaldehyde monitoring in indoor environments. Powered by the Sensirion SFA40 sensing chip, this Gravity‑series air quality sensor selectively detects HCHO molecules while minimizing interference from common household vapors such as alcohol or perfumes. Integrated SHT4x temperature and humidity sensing enables automatic environmental compensation, delivering stable and reliable readings for air monitoring systems. With a convenient Gravity I2C interface compatible with Arduino platforms and other development boards, this environmental sensing module integrates easily into smart home projects, HVAC monitoring equipment, and experimental air‑quality instrumentation.

Zero False Alarms with Selective Electrochemical Detection

Traditional gas sensors frequently produce false alerts when exposed to harmless household scents such as citrus oils, cleaning products, or hand sanitizer. This electrochemical formaldehyde detection module addresses that challenge through advanced electrode materials engineered for extremely low cross‑sensitivity to ethanol (below 0.3%). Such selective detection ensures that rising measurements correspond to genuine formaldehyde concentration changes rather than background odors, making this indoor air quality monitoring board suitable for reliable safety alerts and environmental diagnostics.

Figure: Advanced Electrochemical Principle for Specific HCHO Detection

Laboratory‑Grade Sensitivity Down to 20 ppb

Detecting trace‑level formaldehyde requires extremely high sensing resolution. This precision HCHO monitoring module provides a detection threshold as low as 20 ppb, enabling identification of subtle off‑gassing from building materials, furniture coatings, or interior finishes. Such sensitivity allows environmental researchers, air‑quality developers, and safety monitoring systems to capture concentration changes that many conventional gas sensors overlook. Accurate trace detection makes this air pollution measurement unit suitable for both residential monitoring devices and laboratory‑level experimental setups.

Figure: Ultra-high Sensitivity: Detecting 20ppb is like finding 20 grains in 15 tons of rice.

Integrated Temperature and Humidity Compensation

Environmental conditions such as heat and humidity can introduce measurement drift in gas sensing systems. This formaldehyde sensing board integrates an onboard SHT4x environmental sensor that continuously measures ambient temperature and humidity, enabling automatic real‑time compensation. Such embedded calibration maintains measurement stability across different environments including humid basements, residential living spaces, and office interiors. Simultaneous monitoring of HCHO concentration, temperature, and humidity also provides a richer environmental data set for smart air monitoring platforms.

Figure: Real-time Output: Simultaneous HCHO, Temperature, and Humidity Monitoring.

Figure: Plug-and-Play Gravity I2C Interface with Arduino.

This electrochemical air quality module enables accurate formaldehyde monitoring for a wide range of environments including homes, laboratories, and smart buildings. Integration into air purifiers, ventilation controllers, and indoor environmental monitoring stations allows automatic response when HCHO concentrations increase. Such capability supports safer living spaces, energy‑efficient ventilation control, and experimental indoor air research projects.

Features

  • Sensirion SFA40 electrochemical formaldehyde sensing chip
  • High sensitivity with detection threshold down to 20 ppb
  • Measurement range up to 0–1000 ppb
  • Extremely low cross‑sensitivity to ethanol (<0.3%) to prevent false alarms
  • Integrated SHT4x sensor for temperature and humidity compensation
  • Simultaneous output of HCHO concentration, temperature, and humidity
  • Gravity I2C interface for easy integration with microcontroller platforms
  • Suitable for smart home, HVAC monitoring, and environmental research

Applications

  • Smart Home Air Guardians: Build a monitor that alerts when furniture or interior materials release formaldehyde.
  • Automated Ventilation Systems: Trigger fans or window actuators when HCHO concentration exceeds safe limits (>80 ppb).
  • Smart Air Purifiers: Activate filtration systems only when pollutants are detected, improving energy efficiency.
  • Portable Air Quality Inspectors: Develop handheld monitors for checking indoor environments such as homes, offices, or vehicle cabins.

Specification

  • Typical accuracy: ±20ppb or ±20% m.v (@0~200ppb measurement range)
  • Wide measurement range: 0–1000 ppb
  • Low cross-sensitivity: Cross-sensitivity to ethanol <0.3%
  • Supply Voltage: 3.3–5V
  • Operating Temperature: 0~50℃
  • Operating Humidity:10~90%R.H
  • Operating Current: 80μA(Average@2Hz), 2mA(peak)
  • Size: 32 * 22mm

Shipping List

  • Gravity: SFA40 HCHO Sensor x1
  • Gravity 4pin sensor cable x1
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Gravity: SFA40 Formaldehyde (HCHO) Sensor (0-1000ppb, ±20ppb Accuracy)”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.